Solar-storage boiler connection kit
1641s
The solar-storage boiler connection kit is particularly suitable for integrated systems consisting of a solar storage together with a boiler with storage.
The kit consists of two separate components: a solar thermostatic diverter valve art.1541s and a solar thermostatic mixing valve art.1561s.
The function of the diverter valve is to optimize and manage the fluid contained in the solar storage.
The thermostatic mixing valve allows to maintain constant, at a set value, the mixed water temperature.
When the temperature of the fluid coming from the solar accumulation is lower than the fixed value (T<45°C) set on the solar diverter, the fluid is diverted to the boiler in order to increase the temperature of the same. On the contrary, when the temperature of the fluid coming from the solar storage is greater than the fixed value (T>45°C) set on the solar diverter, the fluid is diverted directly to the thermostatic mixing valve.
An anti-burn function is provided by the valve, stopping the hot mixed water delivery in case of unexpected interruption of the inlet cold water supply, avoiding potentials burns.
The kit, thanks to the special fittings and the presence of swivel nuts, allows an easy and compact installation, both in new and existing systems.
Body in forged brass
Finishing: Chromed plated
Max working pressure: 10 bar
Min inlet cold water temperature: 4°C
Max inlet hot water temperature: 90°C
Diverting temperature: 45°C
Mixed water temperature range: 27°C-55°C
Fluids: water
Code | Size 1 | Size 2 | Version | M | F | ||
---|---|---|---|---|---|---|---|
0164110012 | 1/2" | 45°C | 1 | 7 | |||
0164110034 | 3/4" | 45°C | 1 | 7 |
M = Handle color - F = Finishing color